Optical Specification (Flat Top ThermalAWG)
Parameters | Condition | Specs | Units | ||
Min | Typ | Max | |||
Number of Channels |
| 40 |
| ||
Number Channel Spacing | 100GHz | 100 | GHz | ||
Cha. Center Wavelength | ITU frequency. | C -band | nm | ||
Clear Channel Passband |
| ±0.1 | nm | ||
Wavelength Stability | Maximum range of the wavelength error of allchannels and temperatures in average polarization. | ±0.05 | nm | ||
-1 dB Channel Bandwidth | Clear channel bandwidth defined by passband shape.For each channel | 0.4 |
|
| nm |
-3 dB Channel Bandwidth | Clear channel bandwidth defined by passband shape.For each channel | 0.6 |
|
| nm |
Optical Insertion Loss at ITU grid | Defined as the minimum transmission at ITUwavelength for all channels. For each channel, at all temperaturesand polarizations. |
| 4.5 | 6.0 | dB |
Adjacent Channel Isolation | Insertion loss difference from the meantransmission at the ITU grid wavelength to the highest power, allpolarizations, within the ITU band of the adjacentchannels. | 25 |
|
| dB |
Non-Adjacent, Channel Isolation | Insertion loss difference from the meantransmission at the ITU grid wavelength to the highest power, allpolarizations, within the ITU band of the nonadjacentchannels. | 30 |
|
| dB |
Total Channel Isolation | Total cumulative insertion loss difference fromthe mean transmission at the ITU grid wavelength to the highestpower, all polarizations, within the ITU band of all otherchannels, includingadjacent channels. | 22 |
|
| dB |
Insertion Loss Uniformity | Maximum range of the insertion loss variationwithin ITU across all channels, polarizations andtemperatures. |
| 1.0 | 1.5 | dB |
Directivity(Mux Only) | Ratio of reflected power out of any channel(otherthan channel n)to power in from the input channel n | 40 |
|
| dB |
Insertion Loss Ripple | Any maxima and any minima of optical loss acrossITU band, excluding boundary points, for each channel at eachport |
|
| 0.5 | dB |
Optical Return loss | Input & output ports | 40 |
|
| dB |
PDL/Polarization Dependent Loss inClear Channel Band | Worst-case value measured in ITU band |
| 0.3 | 0.5 | dB |
Polarization Mode Dispersion |
|
|
| 0.5 | ps |
Maximum Optical Power |
|
|
| 23 | dBm |
MUX/DEMUX input/ output Monitoring range |
| -35 |
| +23 | dBm |
IL Represents the worst case over a +/-0.1nmwindow around the ITU wavelength
PDL was measured on average polarization over a+/- 0.1nm window around the ITU wavelength.
Ordering Information
AWG | X | XX | X | XXX | X | X | X | XX |
| Band | Number of Channels | Spacing | 1st Channel | Filter Shape | Package | Fiber Length | In/Out Connector |
C=C-Band L=L-Band D=C+L-Band X=Customize | 16=16-CH 32=32-CH 40=40-CH 48=48-CH XX=Special | 1=100G 2=200G 5=50G X=Special | C60=C60 H59=H59 C59=C59 H58=H58 XXX=special | G=Gaussian B=Broad Gaussiar F=Flat Top | M=Module R=Rack X=Special | 1=0.5m 2=1m 3=1.5m 4=2m 5=2.5m 6=3m S=Specify | 0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/APC 6=LC/PC 7=ST/UPC S=Specify |